Poct Analyzer 4 in 1 Multi-Monitoring Meter Blood Glucose Cholesterol Uric Acid Hemoglobin Meter

Customization: Available
Classification: Imaging Diagnostic Equipment
Certification: CE, ISO13485

Product Description

i

Basic Information

Model NO.
YJ-LBM-01
Classification
Class II
Quality Certification
CE
Safety Standard
En 149 -2001+A1-2009
Product Name
Blood Glucose Monitor
Function
Blood Analysis
Test Time
5 Seconds
Application
Home & Hospital
Origin
China
Power Supply
Portable Power

Product Description

4 Parameter in 1 Multi-Monitoring Meter

● Auto-Strip Recognition
● AVTN Display
● AAA batteries support
● Fast Test Time

YJ-LBM-01 represents high technology for the rapid detection of Glucose, Cholesterol, Uric acid, and Hemoglobin. It realizes clinical instant detection (POCT) and wireless terminal equipment real-time interconnection, transmitting detection results to designated medical systems to support remote medical treatment.

Key Components:
1. Measuring port: Insert test strip to turn meter on
2. C Button: Change date, time, and review results
3. M Button: Enter setting and memory mode
4. Display: Clear symbols and test results
5. Ejection button: Safe removal of used strips
Technical Specifications
Measuring SpeedCholesterol: 15s; Uric Acid/Glucose/Hemoglobin: 5s
Test PrincipleElectrochemical Biosensor
Sample VolumeGlucose/Uric Acid/Hemoglobin: 0.5μL; Cholesterol: 5μL
Sample TypeCapillary and Venous whole blood
Warranty5 Years
Dimensions111mm × 59mm × 16mm (110g)

System Precision

Parameter Concentration Range Precision Result
Total Cholesterol140 - 384 mg/dLCV ≤ 5.65%
Uric Acid2.98 - 18.35 mg/dLCV ≤ 5.12%
Blood Glucose49 - 369 mg/dLCV ≤ 3.10%
Hemoglobin5 - 26 g/dLSD ≤ ±2g/dL / CV ±7.5%

Certifications & Quality

?

Frequently Asked Questions

Which parameters can this device measure?
This 4-in-1 monitor can measure Blood Glucose, Total Cholesterol, Uric Acid, and Hemoglobin levels.
How long does it take to get the results?
Testing for Glucose, Uric Acid, and Hemoglobin takes only 5 seconds, while Total Cholesterol results are ready in 15 seconds.
What is the required blood sample volume?
Most tests require only 0.5μL of blood, while the Total Cholesterol test requires approximately 5μL.
Can this device be used in hospitals?
Yes, it is designed for both home use and hospital environments, supporting POCT (Point-of-Care Testing).
What kind of power supply does the meter use?
The device can be powered by standard AAA batteries or through a portable power supply.
Does the meter recognize test strips automatically?
Yes, the device features Auto-Strip Recognition for easier and more accurate testing.